	<description>Electrical engineering and power transmission</description>
	<items>
		<rdf:Seq>
		<rdf:li rdf:resource="http://www.amcetec.com/article-108-jumper-switch-120-ka" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-107-high-current-and-voltage-disconnectors-swha" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-106-high-voltage-disconnector-40-kv" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-105-high-voltage-disconnectors-1-to-100-000-v-ac-1-000-to-10-000-a" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-104-very-high-current-disconnectors-swd-3000-v-dc-10-000-a-to-200-000-a" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-94-iso-9001-certificate-amc-etec" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-17-jumper-switch" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-13-jumper-switch-150-ka" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-86-newsletter-may-gb" />
		<rdf:li rdf:resource="http://www.amcetec.com/article-84-newsletter-may-2010-fr" />
		</rdf:Seq>
	</items>
</channel>

<item rdf:about="http://www.amcetec.com/article-108-jumper-switch-120-ka">
	<title>JUMPER SWITCH 120 KA</title>
	<link>http://www.amcetec.com/article-108-jumper-switch-120-ka</link>
	<description>

Copper Terminals
Trolley Jumper switch
Large customization possible with: 

Actuators (motor, pneumatic, manual)
Auxiliaries (limit switches, locks, control boxes)
Adaptation to the connectiong busbars.



Main Technical Caracteristics
JUMPER SWITCH 120 KA Electrical Data

Rated current ⇒ 120 kA
Maximum permanent current ⇒ 140 kA
Rated breaking capacity ⇒ 10 V / 120 kA
Maximum breaking capacity ⇒ 20 V / 120kA
Break speed ⇒ &amp;lt; 200 ms 
Useful fife of arcing contact ⇒ ~ 100 breaks / 120 kA
Total voltage drop ⇒ ~ 0,7 V / 120 kA
Dielectric withstand 

Between connections Jumper Sw. “OFF ⇒ 3 kV (6 kV 1 mn)
Between frame and support ⇒ 6 kV (10 kV 1 mn)
 ... more&amp;raquo;  (Tue, 20 Jul 2010 14:39:40 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-107-high-current-and-voltage-disconnectors-swha">
	<title>High Current and Voltage Disconnectors SWHA</title>
	<link>http://www.amcetec.com/article-107-high-current-and-voltage-disconnectors-swha</link>
	<description>

3000 VAC 50/60 Hz - 6 000A on each
Aluminium Terminal
Low and constant voltage drop
Supported by busbars (no frame required)
Large customization possible with:Actuators (motor, pneumatic, manual)
Auxiliaries (limit switches, locks, control boxes)
Adaptation to the connectiong busbars.
According to IEC 60947-3 / IEC 60077-1

High Current and Voltage Disconnectors SWHA Electrical Data

Temperature rise at nominal current (with 40°c max. Ambient temperature) less than ⇒ 50°c
Voltage drop at nominal current less than ⇒ 50 mV
Peak short-circuit current withstand (upon circuit configuration) ⇒ 8 x (nominal current)
Dielectric withstand strength 

Between live parts in open position ⇒ 10 kV - 50 Hz - 1 mn
Between live parts and earth ⇒ 10 kV - 50 Hz - 1 mn
Between auxiliary contacts and earth ⇒ 2.5 kV - 50 Hz - 1 mn
Between motor (AC) and earth ⇒ 2 kV - 50 Hz - 1 mn
 ... more&amp;raquo;  (Tue, 20 Jul 2010 14:18:00 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-106-high-voltage-disconnector-40-kv">
	<title>High Voltage Disconnector 40 kV</title>
	<link>http://www.amcetec.com/article-106-high-voltage-disconnector-40-kv</link>
	<description>

Lightweight
Compact
Strength
Ergonomic
High capacity
Easy Maintenance

 
Technical Caracteristics
High Voltage Disconnector 40 kV Electrical Data

Rated current ⇒ 3150 A
Peak current ⇒ 80 000 A
Rated voltage ⇒ 40 000 V
Peak voltage ⇒ 170 000 V
Dielectric withstand ⇒ 80 kV - 50 Hz - 1mn

 
High Voltage Disconnector 40 kV Mechanical Data

Number cycles before checking wearing parts ⇒ 10 000 cycles
(disconnectors) ⇒ 380 V - 50 Hz - 0.25 kW
Electrical drive by gearmotor ⇒ Less than 20 seconds
Typical duration of opening or dosing operation ⇒ Less than 1 second
 ... more&amp;raquo;  (Tue, 20 Jul 2010 14:08:04 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-105-high-voltage-disconnectors-1-to-100-000-v-ac-1-000-to-10-000-a">
	<title>High Voltage Disconnectors 1 to 100 000 V AC - 1 000 to 10 000 A</title>
	<link>http://www.amcetec.com/article-105-high-voltage-disconnectors-1-to-100-000-v-ac-1-000-to-10-000-a</link>
	<description>

Variable pole contacts geometry
Copper Terminals

 
Technical Caracteristics
High Voltage DisconnectorElectrical Data

Operating tension ⇒ 1 to 100 kV
Operating intensity ⇒ 1 to 100 kV
Dielectric withstand ⇒ 10 to 20 kV

 
High Voltage DisconnectorMechanical Data

Numbers of switches before check of wear parts ⇒ 10 000 cycles
Mechanical stability in « Open » or « Close » positionScrew-bolts connection
Supported by busbar or fixed onto the reinforcedfiberglass resin structure
Wholly rust-proof mechanical shaft andscrews
Visible switch 
Amagnetic
 ... more&amp;raquo;  (Tue, 20 Jul 2010 13:38:28 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-104-very-high-current-disconnectors-swd-3000-v-dc-10-000-a-to-200-000-a">
	<title>Very High Current Disconnectors SWD
3000 V DC - 10 000 A to 200 000 A</title>
	<link>http://www.amcetec.com/article-104-very-high-current-disconnectors-swd-3000-v-dc-10-000-a-to-200-000-a</link>
	<description>

Silver plated Copper terminals ready to be bolted
Aluminium terminals ready to be welded
Compact and fully adaptable
The most energy efficient
The most compact design
IP54 contact chamber

 
Technical Caracteristics
Very High Current Disconnectors SWDElectrical Data

Nominal tension ⇒ 3 000 V DC
Voltage drop at nominal current ⇒ &amp;lt; 30 mV
Temperature rise at nominal current ⇒ Bus bars temperature ≤ 15°c
Maximun current ⇒ 1.5 In DC / 3 In 1mn / 10 In peak 1s
Dielectric withstand ⇒ 10 kV - 50Hz - 1 mn
Current breaking capacity ⇒ 10 A 100 V DC
Protection with arcing contact against residual
currents
Pressurisable protection hood for aggressive
environment IP54
 ... more&amp;raquo;  (Tue, 20 Jul 2010 13:13:03 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-94-iso-9001-certificate-amc-etec">
	<title>ISO 9001 Certificate - AMC ETEC</title>
	<link>http://www.amcetec.com/article-94-iso-9001-certificate-amc-etec</link>
	<description> (Wed, 23 Jun 2010 14:54:00 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-17-jumper-switch">
	<title>Jumper Switch </title>
	<link>http://www.amcetec.com/article-17-jumper-switch</link>
	<description>Specially dedicated to electrolysis according to customer requirements, from 20 kA to 250 kA (Tue, 22 Jun 2010 09:03:43 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-13-jumper-switch-150-ka">
	<title>Jumper Switch  150 Ka</title>
	<link>http://www.amcetec.com/article-13-jumper-switch-150-ka</link>
	<description>Product specially dedicated to electrolysis according to customer requirements (Tue, 22 Jun 2010 09:00:14 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-86-newsletter-may-gb">
	<title>Newsletter - May - GB</title>
	<link>http://www.amcetec.com/article-86-newsletter-may-gb</link>
	<description>


 







 



ENERGY Auditfor High Power CircuitsTo protect your investment in industry, improve productivity and generate savings, it is essential to have a precise and full knowledge of your industrial circuits. A diagnosis of all parts of the circuit allows you to plan all maintenance and repair, and avoid sudden breakdowns that secure your production sustainably. True proactive approach, this audit provides significant and measurable benefits for your plants for years to come. 







Why an ENERGY AUDIT of your industrial circuits?



:: Accurate and Complete Diagnostic of the whole industrial circuit :: Identification of vulnerable areas of the circuit :: Work Tool for users (Maintenance Managers ...) for the years ahead:  Maintenance / Repair / Improvement Plans :: Protection of industrial investment  :: Increase of production and industrial productivity  



Do you need an Energy Audit? 



Emergency:  You have to deal with one of the following problems:  :: Very high temperature in your electrical connections&amp;gt; 120ºC :: Very high electrical resistance -&amp;gt; Very sharp Voltage drop&amp;gt; 50mV  :: Damaged Electrical connections  :: Fast Deterioration of your equipment  :: Damaged Equipment :: Immobilized Industrial production  Operations Maintenance and Improvement:  You would like to work on one of the following items:  :: High temperature in your electrical connections&amp;gt; 80ºC :: High electrical resistance -&amp;gt; High Voltage drop&amp;gt; 5 mV :: Lifespan of your production equipment affected :: Energy Losses 



Request your free Pre-Audit



The pre-energy audit will help you determine the area to repair / maintain / improve on your circuit. This 2-page document will your level of energy consumption per area of the circuit, with the initial conclusions and the scope of study of a possible energy audit. To receive your Pre-Energy audit:  Download Form Pre-Audit Energy here. Simply fill out and return to AMC ETEC with the requested items. You will receive your pre-energy audit within a week, conducted by our experts in electric power engineering.  More ...

 


 ... more&amp;raquo;  (Wed, 05 May 2010 10:22:13 GMT)</description>
</item>

<item rdf:about="http://www.amcetec.com/article-84-newsletter-may-2010-fr">
	<title>Newsletter May 2010 - FR</title>
	<link>http://www.amcetec.com/article-84-newsletter-may-2010-fr</link>
	<description>


 







 



AUDIT ENERGETIQUEpour circuits Haute PerformancePour protéger votre investissement industriel, améliorer la productivité et générer des économies d'énergie, il est essentiel d'avoir une connaissance précise et complète de vos circuits industriels. Un diagnostic de tous les maillons du circuit vous permets de planifier toutes les opérations de maintenance et réparation, et permets d'éviter les pannes brutales qui immobilisent durablement votre production.Véritable démarche ProActive, l'audit énergétique apporte des bénéfices importants et mesurables pour vos usines pour les prochaines années à venir. 



 ... more&amp;raquo;  (Thu, 29 Apr 2010 13:39:44 GMT)</description>
</item>

</rdf:RDF>